Contact with Vietnamecleanroom via phone call
Contact with Vietnamecleanroom via Zalo
Contact with Vietnamecleanroom via Messenger
Contact with Vietnamecleanroom via Viber
phone
Gọi điện
zalo
Zalo
messenger
Messenger
viber
Viber

Wellcome to Vietnam Cleanroom

LENGE VHP Sterilization Chamber / VHP Pass Box
LENGE VHP Sterilization Chamber / VHP Pass Box
LENGE VHP Sterilization Chamber / VHP Pass Box
LENGE VHP Sterilization Chamber / VHP Pass Box

LENGE VHP Sterilization Chamber / VHP Pass Box

In stock

VHP (vaporized hydrogen peroxide) Decontamination Chamber is normally used for sterilization of the outer surface of any object

Contact buy
Share

VHP (vaporized hydrogen peroxide) Decontamination Chamber is normally used for sterilization of outer surface of any object, which is not suitable for AUTOCLAVE & compatible with HYDROGEN PEROXIDE in vapour phase.

iso standard

VHP Sterilization Chamber Operation Principle

A built-in VHP generator heats up the hydrogen peroxide, converting it from liquid to vapor, then blown into the chamber, creating a lethal environment capable of killing bacteria, viruses, and fungi. Each step of the process is fully controlled, guaranteeing perfect performance.

VHP Sterilization Chamber Application

VHP Decontamination Chamber is designed for two different zones of area, for transferring of product from lower classified zone to higher classified zone (Non– sterile area to Sterile area), without affecting the balancing of respective zone, Containment free product transfer to higher classified zone. The Unit is especially suitable for GMP-regulated pharmaceutical companies manufacturing drugs aseptically.

Buồng khử khuẩn VHP Lenge

VHP Sterilization Chamber Features

  • Sterilization process <120min to realize multiple sterilization operations one day.

  • Fully automatic operation, menu can be saved and invoked.

  • Emergency Stop.

  • Adopts clean compressing air for vaporization power which can reduce the impact of the pressure differential when taking air from the room.

  • Decomposition filter can effectively reduce the concentration of VHP remain, and reduce the impact on environment and personnel.

  • Through up downside to reduce the inspection space.

  • Corner sterilization pass box will increase factory space utilization ratio, and improve the distribution.

  • Very low hydrogen peroxide consumption.

VHP: the Process

Air tightness test - Dehumidification - H 2 O 2 Vaporization sterilization - Row of residual - End

Vaporizer Schematic Draw

VHP

Standard size and parameters 

Model

Overall size
W×H×D

Work size
W×H×D

Rated capacity
(L)

Working area
clean class

Sterilization
efficacy

Power
(kw)

LATM288

1200×800×2000

600×800×600

288

Class B

6-log

3

LATM512

1400×800×2200

800×800×800

512

LATM1000

1600×1060×2100

1000×1000×1000

1000

LATM1440

1600×1260×2300

1000×1200×1200

1440

Note: specifications listed below table are only for customers' reference. It is mostly designed and manufactured according to customers' URS.