Interlocking System VCR-X2S
The door interlocking system is used to control the entry of personnel to a secure area such as a clean room, where dust or small particles may be a problem.
What is the VCR-X2S Interlock Lock?
The VCR-X2S Interlock is an auxiliary device designed to ensure that doors in a room cannot be opened simultaneously, thereby maintaining the isolation between clean and non-clean areas.
The VCR-X2S Interlock has the capability to control the opening and closing of two panel doors simultaneously.
When door 1 opens, door 2 is forcibly closed, and door 2 can only be opened after door 1 has closed.
Applications of the VCR-X2S Interlock
- Installed in panel rooms in cleanrooms, cleanrooms, airlocks, intermediate rooms, changing rooms using signaling systems in medical, laboratory, pharmaceutical manufacturing facilities, electronic equipment, semiconductors, office spaces, and more.
- Used for entrance doors, emergency exits, and safety doors.
Quality of the VCR-X2S Interlock
- The VCR-X2S Interlock finds extensive use in the pharmaceutical industry and facilities with cleanrooms.
- Double door interlock: The system automatically checks if both doors are closed; if one door is left open, it signals and sounds an alarm to remind users to close both doors.
- Product Structure: Consists of three components - Control Box, Door Latch, and LED Indicator.
- LED Display: The outer body is made of plastic, combined with LED indicators, making it visually clear and easy to operate.
- High Isolation: This interlock lock is specially designed for air isolation in cleanrooms, often used in shock-absorbing rooms or cleanroom pneumatic valve rooms.
- Quality Materials: Carefully selected materials, low power consumption. This system uses a computer chip for entry, offering high stability, high precision, compact size, and full functionality. The system's power consumption is less than 12W, resulting in minimal heat generation and a longer lock lifespan, making it an ideal product for the clean industry.
Operation of the VCR-X2S Interlock
- When one door opens, the other door automatically closes; both doors cannot be opened simultaneously.
- If one door remains open for too long, an alarm bell will sound to remind staff to close the door.
- In the event of a power outage, both door latches will release, ensuring user safety.
- In case of an emergency, an emergency button can be pressed to force the doors open.
Technical Specifications of the VCR-X2S Interlock
- Double electronic interlock
- Latch Voltage: 12V
- Power Supply: 220V-50Hz
- Lock Cable: 3M, 4m long
- LED Voltage: 5V
- Fully imported lock
- Warranty: 12 months
Components in the VCR-X2S Interlock Box
- Control Box
- Door Latch
- Indicator Light
Installation Diagram for the VCR-X2S Interlock
- The interlock control box will be installed on the ceiling panel and connected to an available power socket (the shorter the distance between the control box and the socket, the better, to save wiring costs).
- The indicator light will be attached to the wall panel, in an area easily observable when entering and exiting, typically placed next to the panel door.
- The door latch will be installed underground inside the wall panel (requires drilling and underground wiring) and can be installed on the side or above the door frame.
- The latch positioning plate will be mounted on the door leaf, corresponding to the location of the door latch installation.
The VCR-X2S and X3S Interlock have gained trust from pharmaceutical factories nationwide, such as Dược Hà Hưng, Dược vật tư y tế Hải Phòng, Davina pharmaceutical factory, Amepro Pharmaceuticals, Đại Bắc Pharmaceuticals, Hoa Linh Pharmaceuticals, the Central Military Hospital 108's Accelerator Facility, and more.
In addition, there are some errors to watch out for during interlock lock installation, such as:
- Securely attach the signal connecting wires to the door latch and indicator light.
Error Alert: The alarm will sound loudly and continuously.
- Align the door latch and latch positioning plate in the same direction (marked as Wifi) on both accessories.
Error Alert: The latch won't work.
- Do not reverse the signal wires between the indicator light and door latch.
Error Alert: It won't install. The signal wire of the door latch is typically slightly larger than the wire for the indicator light, so please pay attention when installing.
- Use wire boxes and tubing to protect signal wires on the ceiling to prevent insects from biting or damaging the wires. Signal wires are different from power cables, and if they are cut or damaged, they are challenging to reconnect.
Cleanroom interlock are essential products for cleanrooms.